Skip to content
Christmas 2026: we are closing our installation schedule. Request your quote soon.
Very N'Ice
Visualisation of an outdoor ice rink in a town, with the service marquee in the background

How to plan an ice rink: space, capacity and facilities

To plan an ice rink you need to know how much space you have, how many people you want skating at once and where the changing area, machinery and spectators will go. As a reference: 3 to 4 m² per skater, a 2 m walkway around the rink and 25 to 50 m² for the changing area.

Written by Very N'Ice technical team · Updated October 2026

1. Measure the available space

Everything starts with the site. We need to know where the rink will go to work out what shape and size will fit, and how much space is left around it for spectators, the changing area and the machinery.

With a few photos, approximate measurements and the location, we can already produce a first layout. If the space has columns, changes in level or an unusual shape, it is better to know from the start: the rink can be adapted to almost any outline.

2. Choose the rink proportions

Rinks usually have a 2 to 1 ratio between length and width: 20 x 10 m, 30 x 15 m or 40 x 20 m. This is not a technical rule but a convention, because those proportions look good and make it easy to skate in a loop.

For specific dimensions and their capacity, see the table of ice rink sizes.

3. Work out the capacity

Capacity is the number of skaters who can be on the ice at the same time. At peak times we allow about 3 m² per skater. For comfortable recreational use we plan on 4 m² per skater.

Surface Comfortable capacity (4 m²) Peak capacity (3 m²)
100 m² 25 33
200 m² 50 66
300 m² 75 100
450 m² 110 150
600 m² 150 200
800 m² 200 266

Bear in mind that hardly anyone comes alone. We allow two or three companions per skater who want to watch, take photos or wait their turn.

4. Leave room for spectators

Because of those companions, the rink needs a walkway about 2 m wide around its whole perimeter. This is where people move around, stop to watch and wait their turn without blocking the entrances.

If the rink is under a marquee, that walkway has to be inside it. A marquee that lets passers-by see people skating draws more visitors than a closed one.

5. Changing area, ticket desk and customer service

Set aside 25 to 50 m², depending on the size of the rink, for the skate racks, the service counter, the ticket desk and the benches where people change their shoes.

6. Soft flooring between the changing area and the rink

This point is often forgotten and it is essential. Skate blades are damaged quickly if people walk on concrete, tiles or any hard surface. The whole route from the changing area to the rink entrance must be covered with carpet, matting, rubber flooring or sports vinyl.

We have different types and samples so the flooring matches the venue’s decoration.

7. Bar and drinks

If there is space, a small bar with a few tables works very well: hot and cold drinks for companions and water for skaters, who are usually thirsty after a while on the ice. Well decorated, it adds to the atmosphere and brings in revenue on top of ticket sales. If there is no room, a few vending machines cover the basics.

To run the numbers on this revenue, try the ice rink profitability calculator.

8. Machinery outside and close by

The chiller goes outside, as close to the rink as possible. The shorter the connection, the better it performs and the less electricity it uses. With its accessories it takes up about 35 m².

Sometimes there is no choice but to put it further away. In that case we add extra thermal insulation to the pipes so no energy is lost along the way.

9. Technical requirements of the site

To install a rink, fixed or mobile, the site needs three things:

  1. A completely level concrete, earth or sand base, with practically no measurable unevenness.
  2. A three-phase power supply with earth, installed by an authorised electrician. We only need the connection terminals.
  3. A drinking water supply with a 3/4-inch (19 mm) hose connection, at normal mains pressure.

We go into more detail in our guide to ice rink technical requirements.

10. From sketch to render

With all of the above, we draw a sketch showing the possible positions of each element and discuss it with you until we agree on the best layout, with an eye on the look of the venue as well.

Once it is approved, we prepare a render of how the whole installation will look. Very N’Ice does not handle decoration or any building work that may be needed; that is the client’s responsibility. You can see how we approach this stage in ice rink design.

Summary of reference areas

Element Guide measurement
Surface per skater 3 to 4 m²
Walkway around the rink about 2 m wide
Changing area, ticket desk and lockers 25 to 50 m²
Machinery and accessories about 35 m² outside
Route from changing area to rink soft flooring (carpet, rubber or vinyl)
  • Customer service marquee with skate racks, chairs and a red carpet beside an outdoor rink
    Customer service marquee with skate racks, chairs and a red carpet beside an outdoor rink
  • Skate hire counter, lockers and changing benches next to an ice rink
    Skate hire counter, lockers and changing benches next to an ice rink
  • Technical drawing of a curved-outline ice rink in a town square
    Technical drawing of a curved-outline ice rink in a town square
  • Render of an ice rink in a shopping centre with the skate counter in the background
    Render of an ice rink in a shopping centre with the skate counter in the background

Frequently asked questions

How much space do I need besides the rink surface?

Allow a walkway about 2 m wide around the whole rink for spectators, 25 to 50 m² for the changing area, ticket desk and skate lockers (depending on rink size) and about 35 m² outside for the machinery. If there is room, a bar area adds revenue.

How many people can skate on an ice rink at once?

At peak times we allow about 3 m² per skater, so a 450 m² rink holds around 150 people at once. For comfortable recreational skating we use 4 m² per skater, around 110 people on the same rink. The owner sets the limit depending on the audience, for example if there are many children.

Where does ice rink machinery go?

The chiller goes outside and as close to the rink as possible, because that way it performs better and uses less power. With its accessories it takes up about 35 m². If it cannot be placed nearby, we add extra thermal insulation to the connecting pipes so no energy is lost along the way.

What facilities does the rink site need?

A completely level concrete, earth or sand base, a three-phase power supply with earth prepared by an authorised electrician, and a drinking water supply with a 3/4-inch (19 mm) hose connection at normal mains pressure. We cover this in detail in our guide to ice rink technical requirements.

Have a project in mind?

Tell us the location, dates and size. We reply with a concrete proposal within 24 working hours.

WhatsAppQuote